List view
Facility Design Process
Facility Design Process
Design Guides
Design Guides
01.0 Arrival
01.0 Arrival
02.0 Administration
02.0 Administration
03.0 Retail
03.0 Retail
04.0 Lockers/Changing
04.0 Lockers/Changing
4.0 Lockers & Changing
4.01 Sightline Vestibule
4.02 Issue/Storage
4.03 Attendant Station
4.04 Housekeeping/Janitor Closet
4.05 Lockers
4.06 Private Changing Room
4.07 Towel Station
4.08 Sinks & Wet Grooming
4.09 Dry Grooming
4.10 Showers
4.11 Toilet Compartment
4.12 Urinals
4.14 Waiting Lounge
4.13 Swimsuit Extractor
4.15 Waiting Hospitality Station
05.0 Relaxation Spaces
05.0 Relaxation Spaces
06.0 Indoor Amenities
06.0 Indoor Amenities
6.0 Indoor Amenities
6.1 Wet Lounge
6.2 Experience Showers
6.3 Steam Room
6.4 Sauna
6.5 Snow Cabin
6.6 Ice Fountain
6.7 Aromatherapy Inhalation Room
6.8 Halotherapy
6.9 Herbal Baths
6.10 Rhassoul
6.11 Hammam
6.12 Hammam Scrub Room
6.13 Plunge Pools
6.14 Sensory Deprivation Rooms
6.15 Reflecting Pool
6.16 Indoor Kneipp Walk
6.17 Herbal Baths
07.0 Spa Treatment Rooms
07.0 Spa Treatment Rooms
7.0 Spa Treatment Areas
7.1 Standard Massage Room
7.2 Multi-Use Treatment Room
7.3 Skincare/Waxing Room
7.4 Couples (Duet) Treatment Room
7.5 Wet Treatment Room
7.6 Vichy Shower Room
7.7 Scrub Room
7.8 Hydrotherapy Room
7.9 Multi-Purpose Treatment Suite
7.10 Advanced Beauty Cabins
7.11 Specialty Treatment Room
7.12 Single Treatment Suite
7.13 Duet Treatment Suite
7.14 Satellite Treatment Pod (single)
7.15 Satellite Treatment Pod (duet)
7.16 Specialty Treatment Suite
Spa Dispensary
08.0 Regenerative Medicine
08.0 Regenerative Medicine
8.0 Regenerative Medicine
8.1 Arrival (RM)
8.2 Seating (RM)
8.3 Restrooms (RM)
Apothecary
8.5 Apothecary Prep & Dispensary
8.6 Apothecary Lounge
RM Dispensary
Housekeeping / Janitor
Records and Copy Room (RM)
Product/Supply Storage (RM)
Copy Room and Records (RM)
Work Stations (RM)
Demonstration Space
Diagnostic Room
Acute Care
Medical Treatment Room
Medical Exam Room
Conference / Group Consultation Space
Consultation Room
IV Terrace/Garden
IV Prep
IV Lounge
09.0 MedSpa
09.0 MedSpa
10.0 Beauty Salon
10.0 Beauty Salon
11.0 Barber/Men’s Salon
11.0 Barber/Men’s Salon
12.0 Spa Culinary
12.0 Spa Culinary
13.0 Support
13.0 Support
13.0 Support
Staff Workspace
Other Mechanical Rooms
Staff Lockers
Janitor/Housekeeping
General Storage
Supervisors Workstations
Product Storage (Secured)
Staff Restroom
Linen Storage
Soiled Linen Cart Staging
Clean Linen Cart Staging
Staff Lounge
Therapist training room
Telephone/Audio/Server Room
Mechanical / Electrical Room
14.0 Fitness
14.0 Fitness
14.0 Fitness
Mind-Body Studio
Physical Therapy Area
Strength Training
Support Staff Office/Work Area
Recovery Area
Stretching Area
Back of House Storage
Restroom(s)
Hospitality Station
Studio Storage
Large Group X Studio
Small Group X Studio
Functional Studio
Personal Training Space
Cardio Training
Fitness Diagnostics
Fitness Trainers Office
Fitness Director Office
Arrival/check-in
15.0 Outdoor Fitness
15.0 Outdoor Fitness
16.0 Outdoor Thermal Amenities
16.0 Outdoor Thermal Amenities
17.0 Landscape
17.0 Landscape
1.0 Pre-Launch - 01 Documentation
1.0 Pre-Launch - 01 Documentation
1.0 Pre-Launch - 02 DLC Partners & Stakeholders
1.0 Pre-Launch - 02 DLC Partners & Stakeholders
1.0 Pre-Launch - 03 Site Audit & Survey
1.0 Pre-Launch - 03 Site Audit & Survey
1.0 Pre-Launch - 04 Systems & Processes
1.0 Pre-Launch - 04 Systems & Processes
18.0 Other Wellness Associated
18.0 Other Wellness Associated
19.0 Circulation
19.0 Circulation
2.0 Launch
2.0 Launch
2.0 Launch - 01 Presentations & Proposals
2.0 Launch - 01 Presentations & Proposals
2.0 Launch - 02 Menus & Marketing Material
2.0 Launch - 02 Menus & Marketing Material
2.0 Launch - 03 Vendor Forms & Information
2.0 Launch - 03 Vendor Forms & Information
2.0 Launch - 04 SOPs & Protocols
2.0 Launch - 04 SOPs & Protocols
2.0 Launch - 05 Staffing & Onboarding
2.0 Launch - 05 Staffing & Onboarding
2.0 Launch - 06 Operational Systems & Software
2.0 Launch - 06 Operational Systems & Software
3.0 Active Operations
3.0 Active Operations
3.0 Active Operations - 01 Documentation
3.0 Active Operations - 01 Documentation
3.0 Active Operations - 02 Vendors Inventories & Quotes
3.0 Active Operations - 02 Vendors Inventories & Quotes
3.0 Active Operations - 03 Menus Brochures & Printed Collateral
3.0 Active Operations - 03 Menus Brochures & Printed Collateral
3.0 Active Operations - 04 SOPs & Protocols
3.0 Active Operations - 04 SOPs & Protocols
3.0 Active Operations - 05 Staffing
3.0 Active Operations - 05 Staffing
3.0 Active Operations - 06 Operational Equip. & Programs
3.0 Active Operations - 06 Operational Equip. & Programs
3.0 Active Operations - 07 Presentations & Proposals
3.0 Active Operations - 07 Presentations & Proposals
Steam Room
Objective
A tile lined room with a generator producing steam usually at temperatures between 40-45 degrees Celsius (104-114 degrees F) and humidity levels at approximately 100%.
Steam Room Variations
Variations
- A Caldarium is another term for a steam bath that originated in ancient Rome. The Caldarium was the heart of the bathing tradition. This has a temperature range from 45-55 degrees C (114-131 degrees F) and 100% humidity.
- A Tepidarium is similar to the steam room and is located adjacent to the Caldarium. This room is generally used as a transition space between the hot and cold amenities. The temperature is lower than the Caldarium at 37-39 degrees C (98-102 degrees F) with humidity at approximately 15-20%.
- A Lanconium is a hot, dry room. This room is kept at the highest temperature 50-60 degrees C (122-140 degrees F) with humidity under 15%.
Space Planning
Locate the steam room adjacent to the experience showers and positioned with other wet amenities, if any. Situate the steam room near the showers to avoid guests traversing dry areas within the locker room.
Design Features
Features:
- Provide vapor-proof and heat resistant construction following criteria specified by local construction regulations and the steam room installer.
- Install a water proof, sloped floor to a drain(s).
- Install stone or tile around the perimeter of the door outside the steam room to prevent adjacent finishes from steam exposure.
- Provide a two tiered bench to allow different temperature seating options.
- Recommended bench depth for a seated position is 45-60cm (18”-24”).
- Recommended minimum bench depth for a reclined position is 76cm (30”).
- Benches should be sloped to prevent condensation from pooling on the benches.
- Install sloped ceilings to prevent condensation from dripping on occupants.
- In order to retain the appropriate level of heat and humidity at user level the typical ceiling height is 2.4m (8’).
- Position the steam outlet nozzles opposite the seating and away from the door to avoid contact burns to occupants. Provide a shield to prevent contact with nozzle or a non scald nozzle.
- Include a focal feature within the steam room.
- Utilize interesting materials within the steam room to create a memorable experience.
- Provide a heat resistant push/pull handle at steam room doors. Handle must remain cool to the touch and be rust resistant.
- Provide equipment operation and life safety signage at appropriate locations.
- Locate steam controls and timers in back of house space to be controlled by the employees.
- Consider a unique cooling feature within the steam room such as; a cold shower, an ice dispenser, a water fountain, or a rinse hose.
- Install robe hooks outside the steam door.
- Steam doors open out of the room. Ensure doors have vision panels to passively monitor the interior.
Flooring and Wall Finishes
Note that traditional tiled steam rooms require re-grouting to maintain proper waterproofing and hygiene levels approximately every 2-5 years.
Furniture and Equipment
Equipment
- Steam Generator Room: Provide an adjacent utility room to remotely locate the steam generator equipment. Provide access from a back of house area for maintenance. The room must be located no greater than 9m (30 feet) from the steam room in order to maintain optimum steam pressure.
- Steam Generator Equipment: Specify a commercial steam generator for continual use with independent thermostat to control the room temperature. Size the generators for the steam room volume. Certain materials require the use of a larger generator. Please consult with the manufacturer prior to purchasing the generator. Provide an aromatherapy dispensing system. Install the required, water supply, inline water softening system, a floor drain, and the necessary electrical supply. Provide blocking within the partition if the generators are wall mounted.
Acoustics
Lighting
Install wet area rated and heat resistant lighting
Temperature and Ventilation
Electrical and Technology Requirements
40-45 degrees Celsius (104-114 degrees F) and humidity levels at approximately 100%.
- Wet area rated and heat resistant audio speakers.
Sanitation and Safety Measures
Duress alarm or emergency shut-off.
Adjacencies
Circulation
FAQs